Soundproof Cabinet Thermal (BTU/hr) & Acoustic (dB(A)) Sizer
Enter your aggregate IT equipment power draw, bare server noise level at 1 meter, and target cabinet attenuation to size heat dissipation and select the right AC-Series enclosure.
How to Use the Interactive Thermal & Acoustic Sizer Above
Enter three project parameters into the live engineering calculator at the top of this page to size your enclosure accurately before requesting a formal quotation:
- Total IT Equipment Load (Watts): Sum the realistic continuous running wattage of all servers, GPUs, switches, NAS arrays, and UPS conversion losses (typically
60–75%of PSU nameplate ratings, or85–95%for sustained AI inference/rendering GPUs). - Internal Server Noise at 1 Meter (
dB(A)): Typical benchmarks:58–64 dB(A)for quiet 2U NAS & PoE switches;68–74 dB(A)for 1U enterprise servers and 4U workstation GPUs;75–82 dB(A)for dense multi-GPU rack servers under full load. - Cabinet Acoustic Attenuation (
dB(A)): Use25–28 dB(A)for AC-12U and AC-18U,26–30 dB(A)for AC-24U-1100, and28–31 dB(A)for AC-32U and AC-42U-PRO.
Engineering Formulas & Sizing Reference Table
Our calculator applies standard thermodynamic and acoustic engineering equations:
- Heat Dissipation (
BTU/hr):BTU/hr = Watts × 3.41214(steady-state electrical power converted to sensible room heat). - Cooling Tons Equivalent:
1 Refrigeration Ton = 12,000 BTU/hr ≈ 3,517 W. A fully loaded3.8 kWAC-24U-1100 rejects12,966 BTU/hr(1.08 tons). - Estimated External Sound Level:
External dB(A) = max(28, Source dB(A) − Cabinet Attenuation dB(A)), capped at typical ambient office noise floor (~28–32 dB(A)).
| Continuous IT Load (W) | Heat Rejection (BTU/hr) |
Minimum Office Circuit | Recommended AC-Series Model | Target External Floor |
|---|---|---|---|---|
400 – 1,500 W |
1,365 – 5,118 BTU/hr |
Single 120V/15A–20A |
AC-12U | <40 dB(A) |
1,500 – 2,400 W |
5,118 – 8,189 BTU/hr |
Dual 120V/20A or 230V/16A |
AC-18U | <42 dB(A) |
2,400 – 3,800 W |
8,189 – 12,966 BTU/hr |
Dual 120V/20A (3,840 W NEC) |
AC-24U-1100 | <45 dB(A) |
3,800 – 4,400 W |
12,966 – 15,013 BTU/hr |
208V/30A or Dual 230V/16A |
AC-32U | <45 dB(A) |
4,400 – 5,400 W |
15,013 – 18,425 BTU/hr |
Dual 208V/30A or 230V/32A |
AC-42U-PRO | <46 dB(A) |
Deep-Dive Technical Engineering Guides
After calculating your baseline BTU/hr and dB(A) targets, review our two companion engineering guides before finalizing room placement and electrical provisioning:
- Soundproof Cabinet Airflow & Thermal Design Guide: Static pressure management, blanking panel discipline, intake delta-T calculations, and ceiling plenum ducting.
- Office Dual 120V/20A GPU Cabinet Power Checklist: NEC 80% continuous derating math, independent breaker verification, and
0UA/B PDU selection without 240V rewiring.
Built to EIA-310-E mounting and acoustic engineering design standards; third-party acoustic/thermal test reports available per project.
Lock In Your Sizing With a 15-Minute Formal Quote
Click Send Sizing to Engineering above or open our 15-Minute Formal Quote Brief with your calculated Wattage, deepest server chassis dimension, and delivery postal code. You can also explore our flagship 24U AI Silent Server Cabinet.
Standard & Custom-Engineered Models
24U AI Silent Server Cabinet (1100 mm Deep)
Flagship 24U acoustic barebone cabinet built for 4U GPU inference nodes and enterprise servers: 1100 mm deep, 3.8 kW continuous extraction, dual 120V/20A PDUs, <45 dB(A) external noise.
Full Datasheet →